BI Technologies Model 66 Potentiometer Datasheet

Standard Resistance Range 10 Ohms to 2 Megohms Standard Resistance Tolerance


BI Technologies Model 66 Potentiometer Datasheet - cover page
Brand
BI
Category
Potentiometer
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
294 KB
Published
11 March, 2014
Updated
25 September, 2023
MD5 checksum
36FBD7915EA9284301FE608C624B5F1B

About this manual

This document provides a comprehensive technical overview of the BI Technologies Model 66, a 3/8 inch square multiturn cermet trimming potentiometer. It covers standard resistance ranges from 10 Ohms to 2 Megohms, with tolerances of ±10% (±20% for values under 100 Ohms) and a power rating of 0.5 Watts at 70°C.

The datasheet details extensive environmental and mechanical performance, including an operating temperature range of –65°C to +150°C, a temperature coefficient of ±100 ppm/°C, and resistance to solder heat up to 260°C. It also includes packaging options such as Box, Tape & Reel, and Ammo Pack, along with specific circuit and mechanical dimensions.

What's inside

  • Electrical Specifications
  • Environmental Specifications
  • Mechanical Specifications
  • Packaging and Ordering Information
  • Circuit Diagram
  • Dimensions and Mechanical Stops
  • Standard Resistance Values

Specifications

Resistance Range10 Ohms to 2 Megohms
Resistance Tolerance±10% (<100 Ohms = ±20%)
Power Rating0.5 Watts at 70°C
Operating Temperature Range–65°C to +150°C
Temperature Coefficient±100 ppm/°C
Actual Electrical Travel20 turns nominal
Dielectric Strength1,000 Vrms
Insulation Resistance1,000 Megohms Min.
Contact Resistance Variation1% or 1 Ohm Max.
Weight0.04 oz. nominal (1.1 grams)

Frequently asked questions

What is the standard resistance tolerance for the Model 66?

The standard resistance tolerance is ±10%, except for values under 100 Ohms which is ±20%.

What is the maximum input voltage for this potentiometer?

The maximum input voltage is 200 Vdc or rms, provided it does not exceed the power rating.

What is the operating temperature range?

The device operates within a temperature range of –65°C to +150°C.

Download PDF (294 KB)