B.B. Battery BP4.5-12RT VRLA Battery Datasheet

FEATURES Maintenance free(no water topping-up required). No free acid(Non-spillable battery). Low self-discharge rate, lower than 3% capacity loss per month. Can be used in any orientation(excluding used inverted). Absorbent Glass Mat technology for efficient gas recombination.


B.B. Battery BP4.5-12RT VRLA Battery Datasheet - cover page
Brand
BBUSER
Category
VRLA Battery
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
270 KB
Published
06 March, 2014
Updated
25 September, 2023
MD5 checksum
FE345E25C0A2790EB929624A6C0C9432

About this manual

This document is a technical datasheet for the B.B. Battery BP4.5-12RT, a maintenance-free VRLA (Valve Regulated Lead Acid) rechargeable battery utilizing Absorbent Glass Mat technology. The unit features a non-spillable design and low self-discharge rate of less than 3% per month.

What's inside

  • Features
  • Specifications
  • Applications
  • Dimensions

Specifications

Nominal Voltage12V
Nominal Capacity4.5Ah @ 20 hour rate
TechnologyAbsorbent Glass Mat
Operating Temperature Range (Charge)0°C~40°C
Internal Resistance<=42mΩ (Fully Charged)

Frequently asked questions

What is the nominal voltage of the B.B. Battery BP4.5-12RT?

The nominal voltage of the battery is 12V.

What is the maximum charge current for this battery?

The maximum charge current is 135A.

What is the operating temperature range for charging this battery?

The battery can be charged between 0°C and 40°C (32°F to 104°F).