This document is a technical datasheet for the BBUSER BP1.2-6 (er1.2-6FR) VRLA rechargeable battery. Key features include being maintenance-free with no free acid, utilizing Absorbent Glass Mat technology for efficient gas recombination, and having a low self-discharge rate of less than 3% capacity loss per month.

What's inside

  • Features
  • Application
  • Specifications
  • Nominal Voltage
  • Operating Temperature Range

Specifications

Nominal Voltage6V
Nominal Capacity1.2Ah @ 20 hour rate F.V.(1.75V/cell)
Approx. Weight300g(0.66lbs.)
TerminalsT1 (Faston Tab 187)
Internal Resistance55m Q (Fully Charged )
Max. Discharge Current18 A(5 sec.)
Max. Charge Current0.36 A

Frequently asked questions

What is the nominal voltage and capacity of the BBUSER BP1.2-6 battery?

The battery has a nominal voltage of 6V and a nominal capacity of 1.2Ah at a 20 hour rate.

What is the approximate weight of the battery?

The approximate weight of the battery is 300g or 0.66lbs.

What is the maximum discharge current for the battery?

The maximum discharge current is 18 A for a duration of 5 seconds.