Key facts
- Brand
- Woodward
- Model
- 723PLUS
- Documents
- 2
- Languages
- EN
- Last added
- 2026-09-29
Start here

Woodward 723PLUS Digital Marine Control Two Engine Mechanical Load Sharing Installation and Operation Manual
The document serves as an original instruction guide for the Woodward 723PLUS Digital Marine Control system, specifically designed for applications involving two engines with mechanical load sharing. It covers general precautions regarding safety and proper use, including warnings about overspeed shutdown devices and electrostatic discharge awareness.
The manual details the installation process, electrical connections, and internal jumpers required to set up the control unit. It describes the operation of speed control and load sharing functions, provides step-by-step procedures for I/O verification and calibration, and explains how to use service and configure menus via a hand-held programmer or PC interface.
Woodward 723PLUS specifications
| Input Power Low Voltage | 18–40 Vdc (24 or 32 Vdc nominal) |
|---|---|
| Input Power High Voltage | 90–150 Vdc (125 Vdc nominal) |
| Power Consumption | 40 W nominal |
| Inrush Current (Low Voltage) | 7 A for 0.1 ms |
| Inrush Current (High Voltage) | 22 A for 15 ms |
| Speed Input Voltage | 1.0–50.0 Vrms |
| Discrete Input | 24 Vdc, 10 mA nominal, 18–40 Vdc range |
| Analog Input | ±5 Vdc or 0–20 mA |
| Analog Output | 0–1 mA or 4–20 mA (max 600 Ω load) |
| Relay Contact Rating | 2.0 A @ 28 Vdc (resistive) |
| Operating Temperature | –40 °C to +70 °C |
Source: Woodward 723PLUS Digital Control Standard Applications
All Woodward 723PLUS documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What communication protocols does the 723PLUS Digital Control support?
It provides two serial ports that can use industry‑standard Modbus (ASCII or RTU) and the Woodward Servlink protocol, and it also supports the LON local operating network protocol.
From: Woodward 723PLUS Digital Control Standard Applications
What are the operating temperature limits for the 723PLUS Digital Control?
The controller is rated for an operating temperature range of –40 °C to +70 °C.
From: Woodward 723PLUS Digital Control Standard Applications
Where can I verify the latest revision of this manual?
You should check manual 26455, Customer Publication Cross Reference and Revision Status & Distribution Restrictions, on the publications page of the Woodward website.
What must be done before disconnecting the battery from the system?
To prevent damage to the control system, you must make sure the charging device is turned off before disconnecting the battery.