UWNTEK UW500 Manuals

ManualLib has 3 documents for the UWNTEK UW500 (Industrial Robot): 3 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 3

Key facts

Brand
UWNTEK
Model
UW500
Documents
3
Languages
ZH
Last added
2026-10-07

Start here

UWNTEK UW500 Distributed Control System Manual

UWNTEK UW500 Distributed Control System Manual

User Manual 48 pages · 4.8 MB · ZH

The UW500 is a distributed control system developed by Zhejiang University Industrial Automation National Engineering Research Center and UWNTEK. It offers high reliability, open architecture, and easy maintenance, with redundant hardware design and a powerful software platform.

The manual describes the three‑layer network (MNet, SNet, CNet), the various control and I/O modules, the engineering software features, and quality management procedures for system deployment and service. This manual is written in Chinese.

Read online

UWNTEK UW500 specifications

CPU frequency720 MHz
Memory capacity256 MB DDR2 SDRAM
Power consumption (module)2.5 W
Operating temperature range-20 °C ~ 60 °C
Input voltage range (power module)176 V ~ 264 V AC
Maximum system network nodes64

Source: UWNTEK UW500 Distributed Control System Manual

All UWNTEK UW500 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What network topologies are supported by the UW500?

The system network can be configured in tree or star topology using Ethernet.

From: UWNTEK UW500 Distributed Control System Manual

How many nodes can the system network accommodate?

The system network can connect up to 64 nodes.

From: UWNTEK UW500 Distributed Control System Manual

What is the maximum size of the real-time database?

The global engineering object real-time database supports a maximum scale of 200,000 points.

From: UWNTEK UW500 Distributed Control System User Manual

What is the minimum resolution for historical data?

The system supports a minimum resolution of 1 second for historical data.

From: UWNTEK UW500 Distributed Control System User Manual

What safety integrity levels are certified for the UW500s and UW510s systems?

The UW500s system is certified for SIL2, and the UW510s system is certified for SIL3.

From: UWNTek UW500s/UW510s Safety Control System User Manual

What is the maximum number of analog inputs supported by the control station?

The control station supports a maximum of 16,384 analog inputs.

From: UWNTek UW500s/UW510s Safety Control System User Manual