Key facts
- Brand
- Trimble
- Model
- SPSx20
- Category
- Industrial Robot
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-16
Start here

Trimble SPSx20 Total Station User Guide
The document is the Version 1.0 User Guide for the Trimble SPSx20 Total Station, published in June 2011 by Trimble Navigation Limited. It serves as an official instruction manual for end users to operate the device safely and effectively.
The guide includes critical safety warnings regarding Class 3R laser radiation, specifically advising against direct eye exposure to the visible or invisible laser sources used for distance measuring. It also details battery safety protocols for the rechargeable Lithium-ion battery.
All Trimble SPSx20 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the Trimble SPSx20 Total Station designed for?
This manual describes how to setup and use the Trimble SPSx20 Total Station.
How often should the instrument be serviced?
Trimble recommends taking the instrument to an authorized service workshop for service and calibration once a year.
What is the wavelength of the laser diode used for distance measuring in DR mode?
The laser diode operates at a wavelength between 630 and 680 nm.
What is the maximum output power of the visible light laser pointer?
The output power for this mode is less than 5 mW.