TOYO VF66 Series Inverter Internal PLC Function Manual
This manual explains how to customize the internal PLC function of TOYO VF66 series inverters using the VF66PCTool software. It details control blocks like CMPA, LAG1, FFWD, and PI controllers, along with ladder logic and dataflow programming. The document covers control cycles (PLCH/PLCL), input/output data flow, and programming guidelines for motor control sequences. It also includes examples of parameter settings and conversion rules for registers.
Read onlineTOYO VF66 series specifications
| Control Cycle (PLCH) | 1ms to 4ms (adjustable by program size) |
|---|---|
| PLCH Division | Auto or manual (1 to 4) |
| PLCL Cycle Limit | Tlimit = 662 - 0.648 × fomax/1us |
Source: TOYO VF66 Series Inverter Internal PLC Function Manual
All TOYO VF66 series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How do I set the speed reference when using PLCH?
When i-01=2, speed reference (ASR) becomes 000001 and items like b-11, b-12, c area, and H-00~H-05 become invalid.
From: TOYO VF66 Series Inverter Internal PLC Function Manual
What happens when I-00 is set to OFF?
MI4 becomes master control of both PLCH and PLCL, and MI5 becomes protect reset.
From: TOYO VF66 Series Inverter Internal PLC Function Manual
What is the control cycle for PLCH and PLCL?
PLCH cycle is 1ms to 4ms, and PLCL cycle is 5ms or 10ms, both adjustable based on program size.
From: TOYO VF66 series inverter internal PLC function manual
What blocks are used for motor control?
Blocks such as CMPA (comparator), LAGI (first-order lag), FFWD (speed correction), DBAN (dead-band), ASRI (speed control), PIA (PI controller), MCAN (torque control), and others are used.
From: TOYO VF66 series inverter internal PLC function manual