Key facts
- Brand
- Speecon
- Model
- 7300PA
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2011-09-30
Start here
SPEECON 7300PA Frequency Transformer User Manual
The SPEECON 7300PA is a frequency transformer designed for AC motor drives, available in 220V and 440V versions covering power ratings from 5HP to 500HP. The device features a front panel with a CHARGE LED indicator and terminals for input/output connections, supporting various control modes including PID and analog input/output. This manual is written in Chinese.
Read onlineSPEECON 7300PA specifications
| Power Rating (220V) | 25~125 HP |
|---|---|
| Power Rating (440V) | 25~500 HP |
| Ambient Temperature (wall‑mounted) | -10 °C to +40 °C |
| Ambient Temperature (indoor) | -10 °C to +45 °C |
| Input Voltage | AC 3‑phase 200‑230 V, 50/60 Hz |
| Output Voltage | AC 3‑phase 0‑230 V, 81 kVA, 212 A |
All SPEECON 7300PA documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What must be done before touching the circuit after power is removed?
Wait until the CHARGE LED goes out, which indicates that the internal capacitors have fully discharged.
What ambient temperature range is recommended for installing the 7300PA?
For wall‑mounted units, -10 °C to +40 °C; for indoor mounted units, -10 °C to +45 °C.
What is the power rating range of the 7300PA?
The 7300PA frequency transformer supports a power rating range from 5HP to 500HP.
What voltage range is required for the 7300PA frequency transformer?
The transformer requires an AC input of 200-240V at 50/60Hz.