Schneider Electric Altivar 31 Variable Speed Drive for Asynchronous Motors Simplified Manual
Schneider Electric Altivar 31 is a variable speed drive for asynchronous motors. This simplified manual covers the minimum implementation for the factory configuration, including preliminary recommendations, installation steps, wiring examples, electromagnetic compatibility, display and key functions, menu access, and fault diagnosis.
It also describes factory settings and parameter adjustment for motor control, inputs/outputs, monitoring, and settings menus. The supplied CD-ROM contains the complete description and all configuration menus; a section covers North American market requirements according to UL and CSA standards. This manual is written in French.
Schneider Altivar 31 specifications
| Single phase supply voltage | 200…240 V 50/60 Hz |
|---|---|
| Three-phase supply voltage | 200…240 V 50/60 Hz |
| Switching frequency | Adjustable from 2 to 16 kHz |
| Maximum ambient temperature | 50°C |
| PTC probe | Controls temperature rise in power module |
All Schneider Altivar 31 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How should the Altivar 31H be mounted?
Install the unit vertically at ±10°, with at least 50 mm free space on each side. Remove the top protective cover for IP20 protection if needed.
What is the maximum switching frequency for the Altivar 31H?
The switching frequency is adjustable from 2 to 16 kHz, with automatic reduction above 4 kHz to prevent overheating.
What is the default motor nominal frequency?
It is 50 Hz unless the motor nameplate frequency differs.
From: Schneider Electric Altivar 31 Variable Speed Drive for Asynchronous Motors Simplified Manual
Is motor phase-loss detection enabled by default?
Yes, it is active in the factory setting.
From: Schneider Electric Altivar 31 Variable Speed Drive for Asynchronous Motors Simplified Manual
What safety precaution must be taken before servicing the ALTIVAR 312?
All power must be removed and a 15‑minute waiting period is required before servicing.
From: Schneider Electric ALTIVAR 312 End-of-Life Instructions
Which component is listed as a hazard for depollution in the ALTIVAR 312?
Electrolytic capacitors are identified as components with operating hazards.
From: Schneider Electric ALTIVAR 312 End-of-Life Instructions