Key facts
- Brand
- Powtran
- Model
- PR5200
- Category
- motor starter
- Industry
- Industrial
- Documents
- 3
- Languages
- EN · ZH
- Last added
- 2026-11-17
Start here

Powtran PR5200 Soft Starter User Manual
This manual explains how to install, configure, and maintain the Powtran PR5200 soft starter. It covers safety precautions, wiring diagrams, control panel operation, protection functions, test running, and RS485 communication.
Key sections include product introduction, installation requirements, main circuit wiring, parameter settings, protection descriptions, fault troubleshooting, and detailed specifications for models ranging from 5.5 kW to 400 kW.
Powtran PR5200 specifications
| Power supply | Utility, self-power station, or diesel generating sets; three-phase AC 380 V ±10%, 50 Hz or 60 Hz |
|---|---|
| Applicable motor | Mouse cage type three-phase asynchronous motor with matching rated power |
| Starting times | Less than 10 times per hour |
| Cooling method | Air cooling |
| Protection level | IP20 |
| Altitude | Below 3000 meters |
| Ambient temperature | -25 °C to +40 °C |
| Relative humidity | Below 90% RH, no dewing |
All Powtran PR5200 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What type of motor can be used with the PR5200 soft starter?
Mouse cage type three-phase asynchronous motors whose rated power matches the soft starter rated power.
How many starts per hour are allowed?
Less than 10 times per hour.
Can capacitors be connected to the output terminals?
No, it is strictly forbidden to connect capacitors to the soft starter output terminals (U, V, W).
What is the cooling method for the PR5200(C) series?
The soft starter uses natural air cooling.
What are the rated power and current ranges for the PR5200 series?
The series covers models from 5.5 kW (11 A) up to 400 kW (800 A), with intermediate ratings such as 7.5 kW (15 A) and 55 kW (110 A).