This manual describes the electrical, optical, and environmental specifications of the GU128x8T-K612C5 dot‑graphic VFD module, as well as the required power supply, RS‑232 interface, and physical dimensions. It also includes a complete list of software commands for controlling the display, setting address, and creating effects.

Detailed sections cover interfacing to the module, communication settings, multi‑drop addressing, macro programming, and graphical data handling. The document provides example command sequences, pin descriptions, and troubleshooting notes for developers integrating the module into their systems.

Read online

NORITAKE-ITRON GU128x8T-K612C5 specifications

Display resolution128 × 8 dots
Supply voltage12.0 VDC ±10%
Supply current500 mA typ.
RS232 input voltage range-24 V to +24 V
RS232 output voltage range-5 V to +5 V
Display area306.95 × 25.35 mm
Dot size / pitch2.15 × 2.95 mm (X) / 2.4 × 3.2 mm (Y)
Luminance1000 cd/m² typ.
Illumination colourBlue‑Green (505 nm)
Operating temperature-40 °C to +85 °C
Operating humidity20 % to 85 % RH @ 25 °C

Source: Noritake Itron EGU128X8T-K612C5 Dot Graphic VFD Module User Manual

All NORITAKE-ITRON GU128x8T-K612C5 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What supply voltage does the module require?

It requires a 12.0 VDC supply with a tolerance of ±10 %.

From: Noritake Itron EGU128X8T-K612C5 Dot Graphic VFD Module User Manual

How can the module be reset to its power‑on state?

Send the hexadecimal command 10 (Software Reset) over the RS232 interface.

From: Noritake Itron EGU128X8T-K612C5 Dot Graphic VFD Module User Manual

What is the default communication baud rate?

The factory default baud rate is set to 9600 baud with no parity.

From: Noritake Itron GU128x8T-K612C5 Dot Graphic VFD Module User Manual

How many display modules can be connected in a multi‑drop system?

Up to 31 display modules can be connected to the same host.