Neptune T-10 Double Check Reverse Flow Meter Parts List
This parts list covers the Neptune T-10 5/8-inch double check reverse flow meter. It lists part numbers, descriptions, and quantities for items such as retaining rings, O-rings, stems, valve assemblies, housings, strainers, and chamber assemblies.
The document also includes spud size, bottom cap, bolt, and spud cap option tables, plus testing procedures for check valves using differential gauge and sight tube methods. It is copyrighted by Neptune Technology Group Inc. in 2019.
Neptune T-10 specifications
| Maximum volume | 100 µl |
|---|---|
| Graduation marks | 10 µl, 50 µl, 100 µl |
| Tip material | Virgin polypropylene |
| Filter material | High‑density polyethylene |
| Autoclave conditions | 120 °C for 10‑15 min at 15 PSI |
| Packaging | 96 tips per rack, 10 racks per pack, 5 packs per case |
Source: Neptune BT100 Series Barrier Tip Product Specification Sheet
All Neptune T-10 documents by type
Questions answered in these manuals
What is the part number for the 5/8” T-10 chamber assembly?
The part number is 9400-600.
From: Neptune T-10 Double Check Reverse Flow Meter Parts List
What pressure must check valve #1 hold back during testing?
It must hold back 1.0 psi in the direction of flow under normal no back-pressure conditions.
From: Neptune T-10 Double Check Reverse Flow Meter Parts List
What graduation marks are on the BT100 Series Barrier Tip?
Graduation marks are indicated at 10 µl, 50 µl and 100 µl.
From: Neptune BT100 Series Barrier Tip Product Specification Sheet
Can the BT100 Series Barrier Tip be autoclaved?
Yes, it can be autoclaved at 120 °C for 10‑15 minutes at 15 PSI.
From: Neptune BT100 Series Barrier Tip Product Specification Sheet