Key facts
- Brand
- MDT
- Model
- MDT10F630
- Category
- microcontrollers
- Industry
- Electronics
- Documents
- 2
- Languages
- ZH
- Last added
- 2026-10-18
Start here

MDT10F630 Microcontroller Migration Guide from PIC16F630
The document details key functional differences between the MDT10F630 microcontroller and the PIC16F630. It highlights that while both devices share similar usage methods, they differ significantly in oscillator configuration (using register 90H), external MCLR pin requirements, and the absence of a Brown-out detection feature on the MDT model.
The guide provides specific instructions for migrating application code from PIC16F630 to MDT10F630. It explains how to modify assembly language registers (specifically 90H) and hexadecimal values in hex files to accommodate the different oscillator setup requirements of the MDT device. This manual is written in Chinese.
All MDT MDT10F630 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Does the MDT10F630 support Brown-out detection?
No, the MDT10F630 does not have a Brown-out function.
From: MDT10F630 Microcontroller Migration Guide from PIC16F630
How can the /MCLR function be enabled on MDT10F630?
It requires using the MDT10F630P13 or MDT10F630S13 package with an external /MCLR pin.
From: MDT10F630 Microcontroller Migration Guide from PIC16F630