Key facts
- Brand
- Kistler-Morse
- Model
- SVS2000
- Category
- Industrial Supply
- Documents
- 4
- Languages
- EN · PT
- Last added
- 2023-10-19
Start here

Kistler Morse SVS 2000™ Quick Reference Manual
This quick reference manual provides step-by-step instructions for setting up and operating the SVS 2000™ system, including mounting, wiring, and calibration procedures. It covers menu navigation, parameter settings, and operational modes such as Run and Function Mode. The guide also includes troubleshooting tips and error messages for common issues.
The manual references the full installation and operation manual for detailed specifications and wiring diagrams, particularly for sensor types and power requirements. It is designed for users who need a concise overview of the system’s setup and operation without diving into the full technical documentation.
Kistler-Morse SVS2000 specifications
| Supported Networks | DeviceNet, EtherNet/IP, Profibus DP |
|---|---|
| DeviceNet Default Node | Node 5 |
| DeviceNet Default Baud Rate | 250k baud |
| Ethernet Default IP Address | 192.168.1.2 |
| Ethernet Subnet Mask | 255.255.255.0 |
| Profibus Default Node | Node 4 |
Source: Kistler-Morse SVS2000 Output Interfaces Installation & Operation Manual
All Kistler-Morse SVS2000 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
The shortest path to a working setup, usually only a few pages.
Questions answered in these manuals
What networks does the SVS2000 output interface support?
It supports DeviceNet, EtherNet/IP, and Profibus DP networks.
From: Kistler-Morse SVS2000 Output Interfaces Installation & Operation Manual
What is the default DeviceNet node address?
The default configuration is Node 5.
From: Kistler-Morse SVS2000 Output Interfaces Installation & Operation Manual
What is the operating voltage range for the SVS2000?
The operating voltage range is 115 V AC ± 10%, 50/60 Hz; 230 V AC ± 10%, 50/60 Hz.
From: Kistler-Morse SVS2000 Installation & Operation Manual
What is the resolution of the SVS2000?
The resolution is selectable from 16 bits to 21 bits in 1-bit increments.
From: Kistler-Morse SVS2000 Installation & Operation Manual
What type of cabinet is the SVS2000 available in?
The SVS2000 is available in an ABS cabinet or an optional stainless steel (304L SS) cabinet.
From: Kistler-Morse SVS2000 Installation and Operation Manual
What sealant is recommended for the SVS2000 installation?
Only Sikaflex 1A or Dow Corning RTV 739/738 sealants are recommended, as others may contain acetic acid harmful to sensors.
From: Kistler-Morse SVS2000 Installation and Operation Manual