Goldammer NR 70 Level Regulator Technical Data Sheet
The document describes the Goldammer NR 70, a non-contact magnetic switch designed for monitoring and regulating liquid levels and temperatures in tanks. It features gas-filled protection contacts that are either fixed or adjustable on a perforated strip within the switching tube.
Key technical specifications include a maximum installation length of 800 mm, a rated pressure of 1 bar, and a medium temperature limit of 100°C. The device supports various connection types (DIN 43650 or M12) and offers different contact functions such as normally open or changeover. This manual is written in German.
Goldammer NR 70 specifications
| Operating voltage | 12V...30V DC |
|---|---|
| Number of functions | max. 3 |
| Switching current (Contact type 01+03) | 0.5A max. |
| Switching potential (Contact type 02+04) | 60 W/VA max. |
Source: Goldammer NR 70-TMA Level Temperature Regulator Data Sheet
All Goldammer NR 70 documents by type
Questions answered in these manuals
What is the maximum installation height for the NR 70 level regulator?
The maximum installation height is 800 mm.
What is the maximum operating pressure for this device?
The maximum operating pressure is 1 bar.
What is the switching difference for this regulator?
The switching difference, also known as hysteresis, is 4 mm.
From: Goldammer NR 70-TMA Level Temperature Regulator Data Sheet