Fill-Rite 700V Series Fuel Transfer Pump Owners Installation, Operation, and Safety Manual

Fill-Rite 700V Series Fuel Transfer Pump Owners Installation, Operation, and Safety Manual

User Manual 48 pages · 1.1 MB · EN

Fill-Rite 700V series fuel transfer pumps (models FR700V, FR701V, FR710V, and FR711V) are 115 and 230 V AC pumps covered by this owners installation, operation, and safety manual. It describes mounting configurations, anti-siphon installation, electrical wiring, operating instructions, pad locking, troubleshooting, accessories, approvals, replacement parts, warranty, fluid compatibility, and technical specifications.

Safety information includes warnings about aircraft and human-consumption fluids, flammable liquids, grounding, and thermal overload protection.

Read online

Fill-Rite 700V Series (FR700V specifications

Voltage115 and 230 V AC models
Maximum lift (gasoline)10 ft (3 m)
Maximum lift (diesel)12 ft (3.7 m)
Check valveBuilt-in with pressure relief valve
Bypass valveIntegral
Motor protectionThermal overload protection
Anti-siphonFactory anti-siphon ready

Source: Fill-Rite 700V Series Fuel Transfer Pump Owners Installation, Operation, and Safety Manual

All Fill-Rite 700V Series (FR700V documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What fluids is the pump not suited for?

It shall not be used to transfer fluids into aircraft and is not suited for fluids intended for human consumption or fluids containing water.

From: Fill-Rite 700V Series Fuel Transfer Pump Owners Installation, Operation, and Safety Manual

What is the maximum lift?

Maximum lift is 10 ft (3 m) for gasoline and 12 ft (3.7 m) for diesel.

From: Fill-Rite 700V Series Fuel Transfer Pump Owners Installation, Operation, and Safety Manual

Why should an anti-siphon device be installed on the 700V Series pump?

It breaks a liquid siphon if there is an open nozzle or a leaking hose below the fluid level in the tank when the pump is turned off. Fill-Rite recommends installing anti-siphon kit # KIT700AS with the tube terminating in the vapor space at the top of the tank.

From: Fill-Rite 700V Series (FR700V, FR701V, FR710V, FR711V) Fuel Transfer Pump Owners Manual

Who should perform the electrical wiring for the pump?

Electrical wiring should be performed only by a licensed electrician in compliance with local, state, and national electrical code NEC/ANSI/NFPA 70, NFPA30, and NFPA 30A, using threaded rigid conduit, sealed fittings, and conductor seal, and the pump must be properly grounded.

From: Fill-Rite 700V Series (FR700V, FR701V, FR710V, FR711V) Fuel Transfer Pump Owners Manual