Key facts
- Brand
- Delta Tau
- Model
- PMAC2
- Category
- Industrial Robot
- Documents
- 2
- Languages
- EN
- Last added
- 2026-10-29
Start here

Delta Tau PMAC/PMAC2 Software Reference Manual
This document serves as the Software Reference Manual for the PMAC and PMAC2 Programmable Multi-Axis Controllers manufactured by Delta Tau Data Systems. Published in January 2008, it covers firmware versions up to V1.17C and provides detailed technical information for configuring and operating the controller software.
The manual is structured to guide users through various aspects of the controller, including command and variable summaries, syntax notes, and specific variable specifications. It details settings for motor definition, safety limits, servo control algorithms (including standard PID and extended options), commutation, coordinate systems, and PLC program commands. It also addresses hardware setup variables for different channel types and encoder configurations.
Delta Tau PMAC2 specifications
| PWM Frequency (Default) | 4.5kHz |
|---|---|
| PWM Resolution | 13+ bits |
| PMAC2 Current Loop Bandwidth | 300Hz |
| Copley Amplifier Current Loop Bandwidth | 3k Hz |
| PWM Signal Levels | TTL levels |
Source: Delta Tau PMAC2 PWM with Copley Digital Application Note
All Delta Tau PMAC2 documents by type
How to use the product for one specific task, with worked examples.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the advantage of using PWM command mode with Copley amplifiers?
The advantage is the increased current loop bandwidth provided by the Copley amplifier, which helps reduce line noise and disturbances.
From: Delta Tau PMAC2 PWM with Copley Digital Application Note
Which Copley amplifiers accept PWM command input?
All Copley Digital amplifiers, including the Xenus, Accelus, and Junus, can take the modern PWM command input for velocity or current mode.
From: Delta Tau PMAC2 PWM with Copley Digital Application Note
What firmware version is covered in this manual?
This manual incorporates the V1.17C firmware addendum.
Who should handle this equipment?