CS Instruments VA 570 Manuals

ManualLib has 2 documents for the CS Instruments VA 570: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
VA 570
Industry
Industrial
Documents
2
Languages
ZH · ES
Last added
2026-09-29

Start here

CS Instruments VA 570 Flow Sensor Installation and Operation Manual

CS Instruments VA 570 Flow Sensor Installation and Operation Manual

User Manual 33 pages · 743 KB · ES

The document serves as a comprehensive guide for the CS Instruments VA 570 flow sensor, covering safety precautions, technical specifications, and physical dimensions. It details the requirements for proper installation within piping systems to ensure accurate laminar flow measurement of gases such as air, nitrogen, oxygen, and natural gas.

The manual provides step-by-step instructions for electrical connection, including wiring diagrams for Modbus RTU and 4-20mA outputs. It also explains how to navigate the device's menu system to configure sensor settings, define reference conditions, set up alarms, and view calibration data. This manual is written in Spanish.

Read online

CS Instruments VA 570 specifications

Measurement principleThermal mass flow sensor
Operating temperature (standard)-40 °C to 180 °C
Operating temperature (ATEX version)-40 °C to 120 °C
Power supply12‑36 V DC
Communication interfaceModbus RTU (EIA/TIA‑485)
Display2" TFT colour display (320 × 240)

Source: CS Instruments VA 550 / VA 570 Flow Sensor User Manual

All CS Instruments VA 570 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What safety precautions must be followed when installing the VA 550 / VA 570?

Installation and commissioning must be performed by qualified personnel who read the manual beforehand and follow all safety instructions, including proper grounding and staying within the limits shown on the nameplate.

From: CS Instruments VA 550 / VA 570 Flow Sensor User Manual

How can the 4‑20 mA current output be configured?

The sensor provides two isolated 4‑20 mA outputs that can be individually adjusted in the "Channel" menu; set Auto to off to define scaling manually.

From: CS Instruments VA 550 / VA 570 Flow Sensor User Manual

What gases can the VA 570 measure?

The instrument is designed to measure mass flow of gases such as air, oxygen, nitrogen, carbon dioxide, argon, and explosive gases like natural gas or hydrogen.

From: CS Instruments VA 570 Flow Sensor Installation and Operation Manual

What is the response time of the sensor?

The t90 response time is less than 3 seconds.

From: CS Instruments VA 570 Flow Sensor Installation and Operation Manual