CRY CRY6151 Electroacoustic Device Analyzer User Manual
The CRY CRY6151 Electroacoustic Device Analyzer is a full-function testing device designed to measure performance indicators for electroacoustic components such as headphones, microphones, and speakers. The manual details the technical specifications, working principles, and input/output ports of the instrument. It also covers the installation of drivers and software, including USB drivers and sound card settings, as well as the installation of the CRY6151 software. This manual is written in Chinese.
Read onlineCRY CRY6151 specifications
| Sweep frequency range | 0.02-20 kHz |
|---|---|
| Sweep amplitude range | 50-5000 mV |
| Sweep output impedance | 0, 32, 150, 300, 450, 600, 750, 900, 1050 Ω |
| Amplitude measurement frequency response | ≤ ±0.5 dB (based on 1 kHz) |
| Electrical signal amplitude range | -80 to 10 dB (0 dB = 1 V) |
| Acoustic signal amplitude range | 50-140 dB (94 dB = 1 Pa) |
| Amplitude measurement error | ≤ ±0.5 dB |
| Background noise | -100 dBV |
| Impedance measurement range | 1-2000 Ω |
| Distortion frequency range | 0.05-15 kHz |
| Distortion measurement range | 0.1-80% |
| Electret microphone voltage range | 0-6.4 V ±50 mV |
| Electret microphone current range | 10-1000 µA |
| Power | 50 Hz, 220 V ±10% |
| Operating environment | 0 to +40 °C, relative humidity ≤80% |
| Dimensions | 360×315×161 mm |
All CRY CRY6151 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What parameters can the CRY6151 measure?
It can measure sensitivity (SPL), impedance, THD distortion, resonant frequency, headphone balance and position, polarity and phase, microphone current and voltage, SNR, microphone directivity, speaker T&S parameters, and telephone receive/send loudness.
What are the power and operating environment requirements?
Power is 50 Hz, 220 V ±10%, and the operating environment is 0 to +40 °C with relative humidity ≤80%.
What is the CRY6151 Electroacoustic Device Analyzer used for?
The analyzer is designed to test headphones, electret microphones, headphone microphone assemblies, speakers, and Bluetooth devices with microphones.
From: CRY CRY6151 Electroacoustic Device Analyzer User Manual
What contact phone numbers are provided for CRY?
The manual lists two phone numbers: 0571-88225198 and 0769-21688120.