Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual

Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual

User Manual 115 pages · 4.2 MB · EN

Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual version 1.2.2 applies to firmware version 1.2.2 and provides safety, compliance, installation, and operating information for the device. It includes FCC, Industry Canada, and ATEX hazardous-location notices, along with power-supply and antenna requirements.

The manual states that the device must be installed by professional installers, grounded properly, and used with approved antenna and coax combinations. It also warns against operating the transmitter within 20 cm of people and specifies a Listed Class 2 power supply rated from 15 Vdc to 30 Vdc with a minimum of 2500 mA.

Read online

Cooper Bussmann 915U-2 specifications

ATEX ratingEx nA IIC T4A, II 3 G, -40 C to +60 C
Hazardous location temperature-40 C to +60 C
External power supplyListed Class 2, 15-30 Vdc, minimum 2500 mA
RF exposure separation distanceAt least 20 cm
EIRP limitNo greater than 36 dBm

Source: Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual

All Cooper Bussmann 915U-2 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What power supply is required for the 915U-2?

A Listed, Class 2 power supply with a rated output between 15 Vdc and 30 Vdc and a minimum of 2500 mA.

From: Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual

What is the operating temperature range?

The device is rated for -40 C to +60 C.

From: Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual

What is the maximum output power allowed for the 915U-2 module?

The device must be installed to maintain an Equivalent Isotropically Radiated Power (EIRP) no greater than 36 dBm.

From: Cooper Bussmann 915U-2 Wireless Mesh I/O and Gateway User Manual

What is the required output voltage range for the external power supply?

The installed power supply must have a rated output between 15 Vdc and 30 Vdc.