Campbell Scientific CA27 and KH20 Eddy Covariance System User Manual
This manual provides detailed instructions for installing and operating the CA27 sonic anemometer and KH20 hygrometer for eddy covariance flux measurements. It covers sensor mounting, calibration procedures, data calculation methods, and troubleshooting common issues. The document also includes information on required auxiliary measurements, power requirements, and system limitations such as rain protection and zero offset drift. Appendixes address water vapor measurements and transducer removal procedures.
Read onlineCampbell Scientific CA27 specifications
| CA27 Path Length | 10 cm |
|---|---|
| CA27 Frequency Response | 40 Hz |
| 127 Frequency Response | greater than 30 Hz |
| KH20 Frequency Response | 100 Hz |
| Battery Runtime | approximately two months |
Source: Campbell Scientific CA27 and KH20 Eddy Covariance System User Manual
All Campbell Scientific CA27 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How should the CA27 and KH20 be protected from rain?
Do not allow the CA27, 127, and KH20 to get wet. Protect them from rain and irrigation systems to avoid damage to transducers and hygrometer seals.
From: Campbell Scientific CA27 and KH20 Eddy Covariance System User Manual
What is the warranty period for the CA27 and KH20?
The CA27 and KH20 are warranted for 12 months from date of shipment, except for batteries which have no warranty.
From: Campbell Scientific CA27 and KH20 Eddy Covariance System User Manual
What is the warranty period for the CA27 and KH20?
The CA27 and KH20 are warranted for twelve (12) months from the date of shipment.
From: Campbell Scientific CA27 and KH20 Eddy Covariance System User Manual
What is the warranty period for KH20 source and detector tubes?
The source and detector tubes are warranted for three (3) months from the date of shipment.
From: Campbell Scientific CA27 and KH20 Eddy Covariance System User Manual
What is the warranty period for the CA27 and KH20?
The CA27 and KH20 are warranted for 12 months from the date of shipment, unless otherwise specified.
From: Campbell Scientific CA27 and KH20 Eddy Covariance System Warranty and Installation Manual
How should the CA27 and KH20 be protected from rain?
Do not allow the CA27, 127, and KH20 to get wet. Protect them from rain and irrigation systems.