Betatherm Series 1 BetaCurve Bare Leaded Thermistors Product Introduction
The Series 1 BetaCurve thermistors are small epoxy‑coated devices with solid tin‑plated lead wires. They provide precise temperature tolerance classifications for applications such as temperature measurement, control, compensation, and thermal sensing in medical, scientific, aerospace and industrial equipment. Interchangeability eliminates the need for individual calibration, as each device matches the published resistance‑temperature curve within defined tolerances.
Key specifications include a temperature range of 0 °C to 70 °C, selectable tolerance options (+0.1 °C to +1.0 °C), a dissipation constant of 0.75 mW, fast 1‑second response in liquids, and a rugged operating envelope from –80 °C to +150 °C. For ordering, contact Betatherm sales via email or phone as listed in the document.
BETATHERM Series 1 BetaCurve Bare Leaded Thermistors specifications
| Temperature range | 0 °C to 70 °C |
|---|---|
| Tolerance options | +0.1 °C, +0.2 °C, +0.5 °C, +1.0 °C (0‑70 °C) |
| Dissipation constant | 0.75 mW |
| Response time | ≈1 s typical in liquids |
| Operating temperature limits | -80 °C to +150 °C |
| Lead wire material | Alloy lead wires (reduced thermal conductivity) |
Source: Betatherm Series 1 BetaCurve Bare Leaded Thermistors Product Introduction
All BETATHERM Series 1 BetaCurve Bare Leaded Thermistors documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What temperature range do the Series 1 BetaCurve thermistors operate in?
They operate from 0 °C up to 70 °C.
From: Betatherm Series 1 BetaCurve Bare Leaded Thermistors Product Introduction
What is the dissipation constant of the BetaCurve thermistors?
The dissipation constant is 0.75 mW.
From: Betatherm Series 1 BetaCurve Bare Leaded Thermistors Product Introduction
What temperature tolerances are available for the Series 1 BetaCurve thermistors?
They are offered with tolerances of ±0.1 °C, ±0.2 °C, ±0.5 °C and ±1.0 °C over the 0 °C‑70 °C range.
From: Betatherm Series 1 BetaCurve Bare Leaded Thermistors Datasheet
What is the usable temperature range for these thermistors?
The devices can operate from –80 °C up to +150 °C.