Key facts
- Brand
- Becker
- Model
- U 5.101
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH · EN
- Last added
- 2026-11-07
Start here

Becker U 5.101 Air Oil Lubricator Operating Instructions
This document provides operating instructions for the Becker U 5.101 air oil lubricator. It includes technical specifications, safety instructions, and details regarding the product's operation and components. The manual is multilingual and covers installation, maintenance schedules, and oil replacement procedures.
Read onlineBECKER U 5.101 specifications
| Vacuum Absolute (Continuous Operation) | 1.0 mbar absolute with opened gas ballast valve |
|---|---|
| Water Vapour Tolerance | max. 7 mbar |
| Water Vapour Capacity | max. 0.9 l/h (at 85°C operating temperature) |
| Nominal Capacity | 50 m³/h |
| Emission Sound Pressure Level | 138 dB(A) |
| Motor Power | 2.2 kW |
| Motor Speed | 1460 min-1 |
| Motor Voltage | 230 V |
| Motor Current | 7.45 A |
| Oil Type | Becker Lube M100 mineral, S100 synthetic, SL100 food |
All BECKER U 5.101 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum water vapour tolerance for the BECKER U 5.101?
The maximum water vapour tolerance is 7 mbar.
What is the motor power and voltage for the BECKER U 5.101?
The motor power is 2.2 kW and voltage is 230 V.
What type of oil is recommended for the Becker U 5.101?
Recommended oils include Becker Lube M 100 (Mineral oil), Becker Lube S 100 (Synthetic oil), and Becker Lube SL 100 (Food).
From: Becker U 5.101 Air Oil Lubricator Operating Instructions
What is the maximum vacuum pressure allowed?
The maximum vacuum pressure is 400 mbar absolute; higher values are not permitted.
From: Becker U 5.101 Air Oil Lubricator Operating Instructions