Key facts
- Brand
- BCHP
- Model
- SPH-300
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2023-02-09
Start here

BCHP SPH-300/SPH-500 High Purity Hydrogen Generator User Manual
The BCHP SPH-300 and SPH-500 High Purity Hydrogen Generators are designed to provide stable hydrogen gas flow for chromatography instruments. The devices utilize a fuzzy control system with automatic tracking to maintain pressure stability within 0.001MPa, featuring two adjustable output pressure settings (L: 4Kg/cm² and H: 6Kg/cm²). They employ membrane separation technology and catalytic transition metal techniques to ensure high purity hydrogen production. This manual is written in Chinese.
Read onlineBCHP SPH-300 specifications
| Hydrogen Purity | 99.999% |
|---|---|
| Flow Rate (SPH-300) | 0-300ml/min |
| Flow Rate (SPH-500) | 0-500ml/min |
| Output Pressure | 4Kg/cm2, 6Kg/cm2 (adjustable) |
| Pressure Stability | < 0.001MPa |
| Power Supply | 220V±10% 50HZ |
Source: BCHP SPH-300/SPH-500 High Purity Hydrogen Generator User Manual
All BCHP SPH-300 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the recommended maximum gas usage?
It is suggested not to exceed half of the maximum production capacity for long-term use to avoid affecting purity and shortening the electrolytic cell life.
From: BCHP SPH-300/SPH-500 High Purity Hydrogen Generator User Manual
What type of water should be used for refilling?
Only secondary distilled water or deionized water should be added when the electrolyte level drops.
From: BCHP SPH-300/SPH-500 High Purity Hydrogen Generator User Manual
What is the maximum recommended daily gas usage for this generator?
Daily gas use should not exceed half of the maximum output to maintain purity and extend the electrolyte cell life.
From: BCHP SPH-300A/SPH-500A High-Purity Hydrogen Generator User Manual
What is the required temperature for regenerating the silica gel in the filter?
The silica gel must be dried at a constant temperature of 120°C for approximately 5 hours.
From: BCHP SPH-300A/SPH-500A High-Purity Hydrogen Generator User Manual