Key facts
- Brand
- Azbil
- Model
- AUD300C1000
- Category
- Industrial Robot
- Documents
- 2
- Languages
- ZH
- Last added
- 2023-11-07
Start here
Yamatake AUD300C1000 UV Sensor Owner's Manual
This manual explains the safe use of the AUD300C1000 advanced UV sensor, including limitations on applications such as personal protection devices, transport control, aerospace, and nuclear equipment. It also details the required safety precautions, warnings, and the need for qualified personnel during installation and maintenance.
Installation steps cover power‑off procedures, proper wiring of the F and G terminals, and guidelines for handling the sensor in environments with steam, oil, or organic solvents. The document describes how to replace the phototube unit (AUD10C) and the maintenance kit (AUD60A1000), and provides a parts list and revision history. This manual is written in Chinese.
All Azbil AUD300C1000 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What does the AUD300C1000 detect?
It detects ultraviolet rays from oil or gas burner flames.
What is the maximum wiring distance stated for the unit?
The maximum wiring distance is 200m.
How often should the phototube unit be replaced?
The phototube unit AUD10C should be replaced after its effective service life of 3 years or 25,000 operating hours.