ZLAN ZLAN8303N/8403N 3G/4G Serial Server User Manual

User manual for the ZLAN ZLAN8303N/8403N 3G/4G serial server, covering hardware description, power-up status, configuration, and RS485 features.


ZLAN ZLAN8303N/8403N 3G/4G Serial Server User Manual - cover page
Brand
ZLAN
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
12
File format
PDF
File size
372 KB
Published
15 October, 2026
Updated
15 October, 2026
MD5 checksum
AE9F19CE7101E90DA62D5D7D54840142

About this manual

This manual describes the ZLAN ZLAN8303N and ZLAN8403N 3G/4G serial servers, which enable remote data acquisition and monitoring of serial devices via 3G/4G networks. The devices support P2P technology for direct communication without fixed IPs and multi-host monitoring to prevent data interference between multiple clients. This manual is written in Chinese.

What's inside

  • Overview
  • P2P Technology
  • Multi-Host Technology
  • Functional Features
  • Technical Parameters
  • Hardware Description
  • Power-Up Process
  • Device Configuration
  • Ethernet Port Usage
  • RS485 Characteristics

Specifications

Operating VoltageDC+9V~DC+24V
Operating Temperature-40°C to 85°C
Storage Temperature-40°C to 90°C
RS-232/485 Baud Rate1200~115200bps
SIM Card Voltage3V, 1.8V
Antenna Interface50Ω/SMA (Female)
Product Dimensions10mm x 20mm x 30mm
RS485 Terminal Count32 devices
RS485 Max Distance1200 meters

Frequently asked questions

What is the operating voltage range for the ZLAN8303N/8403N?

The device operates on a DC voltage range of +9V to +24V.

How many RS485 terminals can a single unit support?

Each unit can support up to 32 RS485 terminal devices.

What is the maximum communication distance for RS485?

The maximum communication distance is 1200 meters.

Does the device require a fixed IP address for P2P connection?

No, the P2P technology allows communication without needing a fixed IP or a server.

Download PDF (372 KB)