User and maintenance manual for Zenit Blue-BluePRO submersible electric pumps, covering safety, installation, electrical connections and maintenance.
This is the English user and maintenance manual for the Zenit Blue-BluePRO electric pumps. It is a translation of the original instructions and begins with a safety section covering installation by skilled staff, electric connections, grounding, protection of the intake and outlet, and the personal protective equipment to be worn when handling the pump in a tank.
The manual then describes conditions of use for the Blue-BluePRO pump range, noise level, handling and lifting, installation methods (mobile post, fixed post, joining foot with guide pipes), electrical connections and rotation-direction check for three-phase models, the floating switch, residual risks and maintenance. Pump data must be recorded on a self-adhesive label supplied with the manual.
| Maximum immersion depth | 20 m beneath the fluid level |
|---|---|
| Temperature of fluid treated | maximum 40 °C, or 60 °C with discontinuous operation |
| Density of fluid treated | maximum 1.1 kg/dm³ |
| pH of fluid to be pumped | between 6 and 14 |
| Start-ups per hour | maximum of 20 evenly spaced start-ups |
| Acoustic pressure level | below 70 dB(A) immersed, below 80 dB(A) in air |
| Recommended shaft size | no smaller than 500 mm x 500 mm x 500 mm |
| Solid passage (DGBlue model) | up to 50 mm |
The immersion depth is a maximum of 20 m beneath the fluid level.
The fluid temperature must not exceed 40 °C, or 60 °C with discontinuous operation.
A maximum of 20 evenly spaced start-ups per hour is allowed.
The pH of the fluid to be pumped must be between 6 and 14.