This is the Chinese user manual for the Yundier passive RS232/RS485 converter, a bidirectional interface converter that turns RS232 TXD and RXD signals into a two-wire, half-duplex RS485 signal. The manual states that no external power supply is needed because the unit draws power from the RS232 port signal pins, and it lists applications such as industrial automation control systems, access control, parking systems, canteen and attendance systems, and highway toll systems.
The document gives the performance parameters (serial standards, asynchronous half-duplex operation, 300–115200 bps, 5 m on the RS232 side and 1200 m on the RS485 side, transparent protocol, -20 °C to 70 °C working environment), the wiring between the RS232 GND/TX/RX and RS485 D+/D- terminals, a short troubleshooting section, and the warranty terms including one-year replacement with customer send-in service. This manual is written in Chinese.
| Serial standards | Compatible with EIA/TIA RS232C and RS485 |
|---|---|
| Working mode | Asynchronous half-duplex |
| Transmission medium | Ordinary cable, twisted pair or shielded cable |
| Transmission rate | 300–115200 bps |
| Transmission distance | 5 m (RS232 end), 1200 m (RS485 end) |
| Communication protocol | Transparent |
| Working environment | -20 °C to 70 °C, relative humidity 5% to 95% |
| Signals | RS232: TXD, RXD, GND; RS485: Data+, Data- |
| Power supply | No external power supply; power taken from the RS232 port signal pins |
| Warranty policy | One-year replacement, customer send-in service |
No. It takes power directly from the signal pins of the RS232 port, so no external supply is required.
The device's D+ and D- terminals connect to the RS485 side's A+ and B- respectively.
Check that the data rate and format of the two communicating devices match, and a 1/4 W 120 Ω matching resistor can be added.
The industrial-grade passive RS232/485 converter has a one-year replacement policy with customer send-in service.