YOUNG TECH YT-320 Pneumatic Amplifier User Manual

This manual provides installation, operation, and maintenance instructions for the YOUNG TECH YT-320 pneumatic amplifier, including troubleshooting and…


YOUNG TECH YT-320 Pneumatic Amplifier User Manual - cover page
Brand
Young Tech
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
420 KB
Published
23 October, 2026
Updated
23 October, 2026
MD5 checksum
E116D2A15C9E72D74AA2235DC100B540

About this manual

The YOUNG TECH YT-320 pneumatic amplifier is designed to receive output pressure from a positioner and supply a high-flow air source to an actuator at the same pressure, thereby increasing the speed of control valve action. It features stable 1:1 pressure supply, high sensitivity, and includes a built-in 100-micron filter to prevent foreign objects from entering the system. The device is available in standard, high-temperature, and low-temperature versions to suit various environmental conditions. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Specifications
  • Action Principle
  • Installation
  • Piping
  • Maintenance
  • Troubleshooting
  • Warranty

Specifications

Max. Supply pressure7 kgf/cm² (100psi)
Max. Signal pressure7 kgf/cm² (100psi)
Input/Output pressure ratio1 : 1
Flow (Cv)2.26
Weight0.76kg

Frequently asked questions

What is the function of the YT-320 pneumatic amplifier?

It receives the output pressure from a positioner installed on a pneumatic control valve and supplies a high-flow air source to the actuator at the same pressure to speed up valve action.

What are the operating temperature ranges for the YT-320?

The standard type operates from -20 to 70°C, the high-temperature type from -20 to 120°C, and the low-temperature type from -40 to 70°C.

What safety precautions are required during installation?

Users must wear protective equipment, ensure the product parameters are not exceeded, and install a pressure reducer before the amplifier to prevent high-pressure gas from entering the actuator directly.

What should be done if the valve does not move when the positioner input signal is applied?

Check if the pressure reducer is supplying air to the positioner and amplifier, verify the positioner's output pressure is normal, and ensure the amplifier's inlet and outlet are not blocked by foreign objects.