User manual for the Yatai YTB-S5/T5 AC motor variable frequency drive, covering specifications, safety, installation, wiring, operation, and parameters.
The manual describes the YTB series AC motor variable frequency drive as the company's newest variety in the series. It says the drive retains the advantages of the earlier series and adds improvements in operation, running, control, and input/output; some models also add RS485 communication. The S5 series is for single-phase 220 VAC input, and the T5 series is for three-phase 380 VAC input.
This concise user manual covers the product overview, model description, technical parameters, safety precautions, installation and structure, terminal wiring, operation, and parameter settings. It includes terminal descriptions and a parameter table with settings such as D000-D046. This manual is written in Chinese.
| Input power | Single-phase 220 VAC or three-phase 380 VAC, 50/60 Hz |
|---|---|
| Frequency range | 0.00-400.00 Hz |
| Overload capacity | 150% for 60 seconds |
| Acceleration/deceleration time | 0.1-6550.0 seconds |
| Frequency resolution | Digital: 0.01 Hz; analog: 0.2% |
| Operating environment | -10°C to +40°C, relative humidity 90% or less, no condensation |
| Modulation method | SVPWM |
| Additional functions | 16-step speed, simple PLC, timer/counter functions |
The S5 series uses single-phase 220 VAC and the T5 series uses three-phase 380 VAC, both at 50/60 Hz.
The frequency range is 0.00 to 400.00 Hz.
The drive has a 150% overload capacity for 60 seconds.
The manual notes that parameters must be unlocked first by setting D001=1.