YAMIT AF-800 Series Automatic Hydraulic Self-Cleaning Screen Filter Service & Maintenance Manual

YAMIT AF-800 Series self-cleaning screen filter service manual covering installation, operation, maintenance, troubleshooting, technical data and appendix.


YAMIT AF-800 Series Automatic Hydraulic Self-Cleaning Screen Filter Service & Maintenance Manual - cover page
Brand
YAMIT
Category
Other
Document type
Service Manual
Language
English
Pages
46
File format
PDF
File size
2.2 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
18F51BBE40DCABA9C58018B009D29AEA

About this manual

The YAMIT AF-800 Series is an automatic hydraulic self-cleaning screen filter for agriculture, municipal water and sewage systems, and industrial applications. It uses coarse and fine screens, a hydraulic piston, hydraulic motor, dirt collector and electronic control unit to start a flushing cycle when differential pressure or time conditions are met.

This service and maintenance manual describes safety instructions, filter description and operation, technical data, initial installation and operation, maintenance and periodic checks, troubleshooting, IPB and appendix schematics. It lists standard features including 2-10 bar operating pressure, 50-3000 micron filtration range, 6V DC or 24V AC control voltage, and 80-liter flush water consumption at minimum working pressure.

What's inside

  • Introduction
  • Safety Instructions
  • Description & Operation
  • Technical Data
  • Initial Installation & Operation
  • Maintenance & Periodical Checks
  • Troubleshooting
  • IPB
  • Appendix
  • International Warranty

Specifications

Minimum operating pressure2 bar (30 psi)
Maximum operating pressure10 bar (150 psi)
Clean filter pressure loss0.1 (2 psi)
Maximum water temperature65°C (149°F)
Filtration range50-3000 micron
Control voltage6V DC, 24V AC
Flush water consumption at minimum working pressure80 liters (21 gallons)
Filter housing materialsCarbon steel coated with baked on epoxy
DC model power source6v supplied by 4 x1.5 “D” size alkaline batteries
AC model power source220 or 110 v AC 50 o 60 Hz with built-in transformer to 24v AC

Frequently asked questions

What is the filtration range of the AF-800 Series?

The manual lists a filtration range of 50-3000 micron.

How long does the flushing cycle take?

The flushing cycle takes about 10 seconds and can be adjusted by the operator.

What type of battery does the control unit use?

The control unit uses a 4 x 1.5V battery; the manual specifies alkaline type only.

How often should the battery be replaced?

The battery can last for 3000 flushing cycles but should be replaced every six months.

Download PDF (2.2 MB)