This manual covers the operation, maintenance, and disassembly procedures for YAMADA IP140S3-TE through IP250S20-TE TOTE type ink pumps.
This document provides instructions for the safe operation and maintenance of YAMADA Corporation's TOTE Type Ink Pumps. It includes specific warnings regarding air pressure limits, combustible gases, and personal safety when operating the pump or handling volatile liquids.
The guide details technical specifications for various models (IP140S3-TE, IP140S12-TE, IP200S25-TE, IP250S20-TE), including discharge pressure and output per cycle. It also outlines procedures for priming the pump, adjusting air pressure regulators, cleaning oil containers, and replacing worn components like gland seals.
| Recommended Oil Type | ISO VG10 general-purpose spindle oil |
|---|
You must use only ISO VG10 general-purpose spindle oil (additive free) to prevent damage or swelling of the acrylic resin cup.
The maximum available pressure of the pump is 100 psi. Setting it higher may damage the pump or cause injury.
Fill the lower pump and elbow stand with ink, open the bleeder valve to remove air, operate until ink discharges from the bleeder valve, then close the valve.