YAMADA TOTE Type Ink Pumps User Manual

This manual covers the operation, maintenance, and disassembly procedures for YAMADA IP140S3-TE through IP250S20-TE TOTE type ink pumps.


YAMADA TOTE Type Ink Pumps User Manual - cover page
Brand
YAMADA
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
1.7 MB
Published
24 October, 2026
Updated
24 October, 2026
MD5 checksum
FA454BD1ABE436554F90ECD35D904B4B

About this manual

This document provides instructions for the safe operation and maintenance of YAMADA Corporation's TOTE Type Ink Pumps. It includes specific warnings regarding air pressure limits, combustible gases, and personal safety when operating the pump or handling volatile liquids.

The guide details technical specifications for various models (IP140S3-TE, IP140S12-TE, IP200S25-TE, IP250S20-TE), including discharge pressure and output per cycle. It also outlines procedures for priming the pump, adjusting air pressure regulators, cleaning oil containers, and replacing worn components like gland seals.

What's inside

  • Warnings
  • Specifications
  • Operating Precautions
  • Pump Priming
  • Adjusting Air Pressure
  • Cleaning Oil Container
  • Maintenance and Inspection
  • Parts List

Specifications

Recommended Oil TypeISO VG10 general-purpose spindle oil

Frequently asked questions

What type of oil should be used for the solvent cup?

You must use only ISO VG10 general-purpose spindle oil (additive free) to prevent damage or swelling of the acrylic resin cup.

What is the maximum operating air pressure?

The maximum available pressure of the pump is 100 psi. Setting it higher may damage the pump or cause injury.

How do you prime the pump?

Fill the lower pump and elbow stand with ink, open the bleeder valve to remove air, operate until ink discharges from the bleeder valve, then close the valve.