Xinya NA8634 Heat Pump Water Heater Controller User Manual

User manual for the Xinya NA8634 controller that manages temperature, defrost, alarms and timed operation of heat‑pump water heaters.


Xinya NA8634 Heat Pump Water Heater Controller User Manual - cover page
Brand
苏州新亚
Category
Water heater
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
231 KB
Updated
06 October, 2026
MD5 checksum
7E7938B9718003015DCDB2F10C107FB3

About this manual

The NA8634 controller is designed for heat‑pump water heaters and provides three temperature sensors, three control outputs and an external alarm input. It supports temperature display and control, automated defrost, exhaust temperature protection, external alarm handling and time‑based operation modes.

The manual describes the main functions, technical specifications, operation procedures such as setting temperature, time, work mode, economic schedule, advanced parameter settings, and alarm handling, along with wiring diagrams and safety notes. This manual is written in Chinese.

What's inside

  • 主要功能及技术指标
  • 操作指南
  • 显示功能
  • 设置水温
  • 设置时间
  • 设置工作模式
  • 设置经济模式工作时段
  • 高级设置
  • 告警处理
  • 基本工作原理

Specifications

Temperature display range-50~150 °C
Temperature setting range0~100 °C
Power supply voltage220 V ±10 %
Operating environment temperature-10 °C~50 °C
Output load capacity (compressor)10 A/250 VAC
Output load capacity (other outputs)2 A/250 VAC
Temperature sensor typeNTC R25=5kΩ, B=3470 K

Frequently asked questions

How can I adjust the controller’s clock?

Press the “⊙” key, then use the “5” or “6” keys to change hours and minutes, pressing the key again to confirm each step.

What alarm code indicates a water‑probe fault?

A water‑probe fault triggers alarm code A21 and the display shows “---”.

How is the external alarm input configured?

The external alarm can be set to normally open, normally closed, or disabled via parameter F50, and its automatic recovery count and reset time are set with F51 and F52.