Xinda CF6B-2A Thyristor Controller Technical Manual

The Xinda CF6B-2A Thyristor Controller Technical Manual provides specifications, wiring, operation, installation, and troubleshooting guidance.


Xinda CF6B-2A Thyristor Controller Technical Manual - cover page
Brand
信达
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
905 KB
Published
09 December, 2011
Updated
08 October, 2026
MD5 checksum
8C24746B68DCFFA30CD5ADA2DE4CCB5F

About this manual

The CF6B-2A thyristor controller is a three‑phase phase‑shift controller with dual‑loop speed and current regulation, suitable for full‑bridge, half‑bridge and half‑wave rectifier circuits used in DC motor speed control and other three‑phase rectifier applications. It features integrated structure, automatic phase‑sequence adaptation, and strong interference immunity.

The manual covers the controller’s technical parameters, operating principle, mechanical structure, installation dimensions, wiring diagrams, usage instructions, and a troubleshooting section. Appendices include circuit diagrams and a table of power‑module components for the U3TTQ‑U3TTY series. This manual is written in Chinese.

What's inside

  • Overview
  • Technical Specifications
  • Operating Principle
  • Structure and Installation
  • Usage Instructions
  • Troubleshooting and Countermeasures
  • Appendix: Diagrams
  • Appendix: Power Module Table

Specifications

Trigger pulse width≥1 ms
Trigger pulse current peak≥800 mA
Trigger pulse voltage peak≥8 V
Phase‑shift range0–170°
Input control voltage0–15 V
Operating temperature-25 °C to +40 °C
Relative humidity<85 %
Power supplyThree‑phase 380 V ±10 % 50 Hz
Power consumption<10 W
Dimensions262 × 192 × 60 mm
Weight1.6 kg

Frequently asked questions

What is the input control voltage range for the CF6B-2A controller?

The controller accepts an input control voltage of 0 to 15 V, or it can be driven by an external potentiometer.

How does the controller protect against overcurrent?

When the main circuit current exceeds the set over‑current value, the trigger pulse shifts to β = 35° and self‑locks; the protection resets after the reset switch is pressed or power is cycled.

Which terminals connect to the thyristors for phase A, B, and C?

Terminal 1# connects to A+ and A‑; terminal 2# to B+ and B‑; terminal 3# to C+ and C‑ of the thyristors.

Download PDF (905 KB)