Chinese user manual for Xiangyi GW series eddy current dynamometers, covering operation, installation, specs and maintenance.
The GW series eddy current dynamometer is a load device for testing the performance of various power machines such as internal‑combustion engines, electric motors and transmission components. It features a simple structure, high braking torque, precise measurement and fast dynamic response.
The manual provides the main applications, mechanical structure, technical specifications, installation and calibration procedures, maintenance guidelines, accessory lists and after‑sales service information. This manual is written in Chinese.
| Cooling water pressure | 0.2–0.4 MPa |
|---|
The cooling water pressure should be between 0.2 and 0.4 MPa.
A 60‑pulse magnetic speed sensor is used for speed measurement.