User manual for Wilo SC circulation pumps, covering installation, operation modes, wiring, and technical specifications.
This manual provides instructions for installing and operating Wilo SC circulation pumps in hot water heating systems. It details pump components, wiring procedures, and three operating modes: constant speed, Δp-v, and Δp-c. Technical specifications, performance curves, and fault troubleshooting are also included.
The pump must be installed in pressurized water systems only. Wiring must be performed by a qualified technician. Operating modes can be adjusted using the control button, with factory settings preset for constant speed and curve III. This manual is written in Chinese.
| Power Supply | 1 ~ 230 V, 50 - 60 Hz |
|---|---|
| Power Input (Min./Max.) | 3 / 43 W for Wilo PARA 25/6 SC, 2 / 75 W for Wilo PARA 25/8 SC |
| Max. Speed | 4300 rpm for Wilo PARA 25/6 SC, 4800 rpm for Wilo PARA 25/8 SC |
| IP Rating | IPX4D |
| Fluid Working Temperature | 0 - 100 °C at 58 °C ambient temperature |
| Max. Static Pressure | 10 bar |
| Max. Head | 6.7 m for Wilo PARA 25/6 SC, 8.4 m for Wilo PARA 25/8 SC |
The pump has three operating modes: constant speed, Δp-v (variable differential pressure), and Δp-c (constant differential pressure).
Hold the operating button for at least 4 seconds while the pump is off, then reconnect power.
The maximum power input is 75 W.