WeEn BT134-600D 4Q triac product data sheet with electrical, thermal, and switching specifications for the SOT82-packaged device.
WeEn BT134-600D is a planar passivated very sensitive gate four-quadrant triac in a SOT82 (SIP3) plastic package. This document is a product data sheet covering general description, features and benefits, applications, quick reference data, pinning, ordering, marking, limiting values, thermal characteristics, characteristics, and package outline.
The device is intended for general purpose bidirectional switching and phase control where high sensitivity is required in all four quadrants, and for direct interfacing to microcontrollers, logic integrated circuits, and other low power gate trigger circuits. Its listed characteristics include a 600 V repetitive peak off-state voltage, 4 A RMS on-state current, and typical gate trigger currents from 2 mA to 5 mA depending on quadrant.
| Repetitive peak off-state voltage | 600 V |
|---|---|
| RMS on-state current | 4 A |
| Non-repetitive peak on-state current | 25 A |
| I2t for fusing | 3.1 A2s |
| Rate of rise of on-state current | 50 A/μs (T2+ G+, T2+ G-, T2- G-); 10 A/μs (T2- G+) |
| Peak gate current | 2 A |
| Peak gate power | 5 W |
| Average gate power | 0.5 W |
| Storage temperature | -40 to 150 °C |
| Junction temperature | 125 °C |
| Thermal resistance, junction to mounting base | 3.7 K/W (half cycle); 3 K/W (full cycle) |
| Thermal resistance, junction to ambient | 100 K/W |
| Gate trigger current | 2 mA typical (T2+ G+); 2.5 mA typical (T2+ G-, T2- G-); 5 mA typical (T2- G+) |
| Holding current | 1.2 mA typical, 10 mA maximum |
| On-state voltage | 1.4 V typical, 1.7 V maximum |
| Gate trigger voltage | 0.7 V typical, 1 V maximum at 25 °C; 0.25 V minimum, 0.4 V typical at 125 °C |
| Off-state current | 0.1 mA typical, 0.5 mA maximum |
| Rate of rise of off-state voltage | 5 V/μs |
| Gate-controlled turn-on time | 2 μs |
SOT82 (SIP3) plastic package.
600 V.
4 A at a mounting base temperature of 107 °C or less.
General purpose low power motor control.
2 mA typical, with a 5 mA maximum.