WeatherBond X-Tenda Coat Acrylic Base Coat Technical Data Bulletin

Technical data bulletin for WeatherBond X-Tenda Coat Acrylic Base Coat, a one-component low-VOC water-borne base coat for aged single-ply roofing membranes.


WeatherBond X-Tenda Coat Acrylic Base Coat Technical Data Bulletin - cover page
Brand
WeatherBond
Category
Chemical products
Document type
Product Leaflet
Language
English
Pages
1
File format
PDF
File size
113 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1DA470666303C28B9636D619013E98F1

About this manual

This technical data bulletin describes WeatherBond X-Tenda Coat Acrylic Base Coat, a one-component, low-VOC, water-borne base coating designed for application to aged single-ply roofing membranes. The document states that it is a high-performance base coat for hard-to-coat surfaces such as aged Hypalon®, PVC, TPO and EPDM roofing, and that it removes the need for costly replacement and for pre-treating EPDM with a caustic solution before coating.

The bulletin lists features and benefits, application instructions, ratings and approvals, storage requirements, and a table of typical properties and characteristics measured against ASTM D6083. It notes that cool temperatures and high humidity retard cure and that the product is for industrial/commercial applications only.

What's inside

  • Overview
  • Features and Benefits
  • Application
  • Typical Properties and Characteristics
  • Ratings and Approvals
  • Storage

Specifications

ColorBuff
Theoretical Coverage66 sq ft/gal
Wet Adhesion – Hypalon (pli)2 minimum required; 6.1 typical result
Wet Adhesion – TPO (pli)2 minimum required; 4.9 typical result
Wet Adhesion – EPDM (pli)2 minimum required; 2.5 typical result
Volume Solids>50% required; 54 ± 2 typical
Weight Solids>60% required; 67 ± 2 typical
Weight per Gallon11.88 lbs
Viscosity (KU)85 – 141 required; 110 ± 10 typical
Drying Time4 – 8 hours, depending on temperature and humidity
Storage temperature40°F to 90°F (4°C and 32°C)
Shelf life24 months if unopened containers are stored as specified

Frequently asked questions

At what temperature should X-Tenda Coat Acrylic Base Coat be applied?

It should be applied at temperatures above 50°F (10°C), and only when weather conditions permit drying before rain, dew or freezing temperatures.

Can X-Tenda Coat Acrylic Base Coat be used as a top coat?

No. The instructions state that it must not be used as a top coat.

How should X-Tenda Coat Acrylic Base Coat be stored?

Store materials between 40°F and 90°F (4°C and 32°C), out of direct sunlight and protected from freezing during transit, handling, storage and installation.

What is the shelf life of X-Tenda Coat Acrylic Base Coat?

24 months if unopened containers are stored between 40°F and 90°F (4°C and 32°C) and out of direct sunlight.

Download PDF (113 KB)