About this manual

The VHP® Series Four® Gas Enginator® Generating System (model VHP3604GSI/GSID) delivers 500‑600 kW of continuous power and incorporates Waukesha’s Engine System Manager (ESM®) for integrated control of spark timing, speed, air‑fuel ratio, and diagnostics. The system includes a turbocharged, intercooled gas‑fueled engine with six interchangeable cylinder heads and a brushless exciter generator.

Standard equipment covers a dry‑type air cleaner, manual barring device, heavy‑duty bearings, a control system with MODBUS RTU communication, multiple cooling options (radiator, heat exchanger, or remote radiator), and a full suite of monitoring sensors for oil pressure, temperature, and exhaust O₂. Performance tables provide fuel consumption, heat rejection, and airflow data for both 50 Hz and 60 Hz configurations.

What's inside

  • Standard Equipment
  • Control System
  • Cooling System
  • Fuel System (GSI)
  • Fuel System (GSID)
  • Generator
  • Performance Data
  • Engine Monitoring Devices
  • Safety Standards

Specifications

Continuous Power Rating500‑600 kW
Bore × Stroke9.375" (238 mm) × 8.5" (216 mm)
Voltage / Frequency480/277 V 60 Hz and 400/230 V 50 Hz
Fuel Pressure (GSI)30 PSIG min – 50 PSIG max
Compression Ratio8:1

Frequently asked questions

What is the continuous power rating of the VHP3604GSI/GSID Enginator?

The Enginator is rated for 500 kW to 600 kW of continuous power.

What cooling system options are available for this Enginator?

Customers can choose a mounted radiator with pusher fan, a heat exchanger with expansion tanks, or a remote radiator cooling system.

Which safety standards does the control system meet?

The control system complies with Canadian Standards Association Class I, Division 2, Group D hazardous‑location requirements.

What are the fuel pressure specifications for the GSI fuel system?

The GSI fuel system operates with a pressure range of 30 PSIG minimum to 50 PSIG maximum.