Water Specialist WS1.5/WS2/WS2QC Control Valve Service Manual

Service manual and drawing guide for Water Specialist WS1.5, WS2, and WS2QC control valves, covering installation, specifications, troubleshooting, and…


Water Specialist WS1.5/WS2/WS2QC Control Valve Service Manual - cover page
Brand
Water Specialist
Category
Other
Document type
Service Manual
Language
English
Pages
52
File format
PDF
File size
8.5 MB
Published
02 November, 2026
Updated
02 November, 2026
MD5 checksum
1AB4A5441D86998E753CEA07B9CB87FB

About this manual

This document serves as a comprehensive service manual and drawing guide for Water Specialist WS1.5, WS2, and WS2QC control valves. It provides detailed installation instructions, system startup procedures, and specific troubleshooting steps for various valve cycle positions. The manual includes exploded views and instructions for disassembling and servicing key components such as the drive assembly, pistons, and injector caps.

What's inside

  • Installation Summary
  • General Specifications
  • Valve Port Orientation Diagrams
  • Installation Instructions
  • System Startup
  • Troubleshooting Procedures
  • Control Valve Cycle Positions
  • Base Assemblies
  • Injector Graphs
  • Motorized Alternating Valve Applications

Specifications

Minimum Operating Pressure20 psi (138 kPa)
Maximum Operating Pressure125 psi (862 kPa)
Minimum Operating Temperature40°F (4°C)
Maximum Operating Temperature110°F (43°C)
Service Flow Rate (WS1.5)70 gpm (265 lpm)
Service Flow Rate (WS2)115 gpm (435 lpm)
Service Flow Rate (WS2QC)125 gpm (473 lpm)
Backwash Flow Rate (WS1.5)52 gpm (192 lpm)
Backwash Flow Rate (WS2)80 gpm (303 lpm)
Backwash Flow Rate (WS2QC)85 gpm (322 lpm)
Inlet/Outlet Size (WS1.5)1.5" Female NPT or BSPT
Inlet/Outlet Size (WS2/WS2QC)2" Female NPT or BSPT
Drain Line Size (WS1.5)1.25" Female NPT
Drain Line Size (WS2/WS2QC)1.5" Female NPT

Frequently asked questions

What chemicals can damage the control valve?

Hydrocarbons such as kerosene, benzene, and gasoline may damage products containing O-rings or plastic components.

Can the control valve be used on water supplies containing hydrocarbons?

No, the product should not be used on water supplies that contain hydrocarbons like kerosene, benzene, or gasoline.

What is the recommended lubricant for black O-rings?

A silicone lubricant may be used on black O-rings, though it is not strictly necessary.

What is the required clearance for servicing WS1.5 valves?

One foot of clearance is required to service WS1.5 valves.