Service manual and drawing guide for Water Specialist WS1.5, WS2, and WS2QC control valves, covering installation, specifications, troubleshooting, and…
This document serves as a comprehensive service manual and drawing guide for Water Specialist WS1.5, WS2, and WS2QC control valves. It provides detailed installation instructions, system startup procedures, and specific troubleshooting steps for various valve cycle positions. The manual includes exploded views and instructions for disassembling and servicing key components such as the drive assembly, pistons, and injector caps.
| Minimum Operating Pressure | 20 psi (138 kPa) |
|---|---|
| Maximum Operating Pressure | 125 psi (862 kPa) |
| Minimum Operating Temperature | 40°F (4°C) |
| Maximum Operating Temperature | 110°F (43°C) |
| Service Flow Rate (WS1.5) | 70 gpm (265 lpm) |
| Service Flow Rate (WS2) | 115 gpm (435 lpm) |
| Service Flow Rate (WS2QC) | 125 gpm (473 lpm) |
| Backwash Flow Rate (WS1.5) | 52 gpm (192 lpm) |
| Backwash Flow Rate (WS2) | 80 gpm (303 lpm) |
| Backwash Flow Rate (WS2QC) | 85 gpm (322 lpm) |
| Inlet/Outlet Size (WS1.5) | 1.5" Female NPT or BSPT |
| Inlet/Outlet Size (WS2/WS2QC) | 2" Female NPT or BSPT |
| Drain Line Size (WS1.5) | 1.25" Female NPT |
| Drain Line Size (WS2/WS2QC) | 1.5" Female NPT |
Hydrocarbons such as kerosene, benzene, and gasoline may damage products containing O-rings or plastic components.
No, the product should not be used on water supplies that contain hydrocarbons like kerosene, benzene, or gasoline.
A silicone lubricant may be used on black O-rings, though it is not strictly necessary.
One foot of clearance is required to service WS1.5 valves.