Installation, operation and maintenance manual for the Vulcan HDS submersible pump agitator, covering safety, installation, maintenance and troubleshooting.
The Vulcan HDS submersible pump agitator manual, document A1540, revision 0 dated 23 January 2014, is written for technical personnel. It covers general information, transportation and storage, receiving inspection, safety, installation, operation, maintenance, troubleshooting, and pump data.
The manual includes procedures for mounting and positioning, handling and lifting, pipe and electrical connections, start-up and shut-down, preventative maintenance, wet-end assembly and disassembly, and fastener assembly torque. It also references the Baldor-Reliance AC Submersible Motors Installation & Operation Manual MN414 for electric submersible motor maintenance.
| Storage temperature range | 10°C (50°F) to 49°C (120°F) |
|---|---|
| Storage relative humidity | Maximum 60% |
| Minimum winding resistance | 5 Meg ohms |
| Shaft rotation during storage | 15 times every 30 days |
It must be transported in a vertical position in the normal operating orientation.
The shaft must be rotated 15 times every 30 days.
Inspect each pump immediately upon arrival and report any shipping irregularities or damage to the transportation company and Vulcan Pumps.
The warranties extend for twelve (12) months from the date of purchase.