VEVOR DP120356L/DP123756/DP120556S/DP120556HZ Single Phase Induction Motor User Manual

User manual for VEVOR single phase induction motors models DP120356L, DP123756, DP120556S and DP120556HZ, covering safety, specs, wiring and troubleshooting.


VEVOR DP120356L/DP123756/DP120556S/DP120556HZ Single Phase Induction Motor User Manual - cover page
Brand
VEVOR
Category
AC Motors
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
335 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
134A4EB45D2DC192E0B571AC5CAB2D8D

About this manual

This manual covers VEVOR single phase induction motors with models DP120356L, DP123756, DP120556S and DP120556HZ. It includes safety warnings, technical information, connection and wiring methods, and common problems with remedies.

The motors are rated for 230V, 60 Hz, single phase operation with a 3450 RPM rated speed. The manual also lists model-specific horsepower, frame size, rated current, shaft dimensions, enclosure, insulation, service factor, duty, protection and ambient temperature limits.

What's inside

  • Safety Warnings and Precautions
  • Technical Info
  • Connection Method
  • Wiring Method
  • Common Problems and Remedies

Specifications

Model NoDP120356L, DP123756, DP120556S, DP120556HZ
Horsepower3HP, 3.7HP, 5HP SPL, 5HP
Frame Size56, 56, 56, 56HZ
Rated Current15.0A, 17.2A, 15.0A, 22.0A
Shaft Length1.88 in, 1.88 in, 1.88 in, 2.25 in
Shaft Diameter9/8 in Keyed, 9/8 in Keyed, 9/8 in Keyed, 118 in Keyed
Rated Speed3450 RPM
PhaseOne / Single Phase
Voltage230V
Frequency60 Hz
RotationCCW/CW
EnclosureODP
InsulationF
Service Factor1
DutyCont.
Protectionp23
Design Ambient40 C
Overload ProtectionOverload Protection with Manual Reset

Frequently asked questions

What should I do if the motor does not work when powered on?

Check that the power supply voltage is correct, verify the wiring matches the diagram, and press the red protector button until it clicks before reconnecting power.

What should I do if the motor rotates slowly and cannot start normally?

Check the power supply voltage, verify the wiring matches the diagram, and check the motor capacitance.

What should I do if the motor heats up and stops after running?

The motor may be overloaded. Let it cool for half an hour, then press the red protector button to reset and try again.

What should I do if the shaft cannot be turned manually when the motor is received?

The concentricity may have been damaged during transport. Tap the shaft, front end cover and back end cover with a wooden or rubber hammer until the shaft turns freely.