Operating manual for Verderflex VF series peristaltic hose pumps covering safety, installation, operation, and maintenance.
This manual provides comprehensive instructions for the safe operation and servicing of Verderflex VF series peristaltic industrial hose pumps (models VF 5 through VF 80). It includes safety warnings, intended use, layout and function, transport, storage, installation, pipe planning, assembly, hose installation, electrical connection, operation, maintenance, troubleshooting, and technical specifications.
The document is structured for operating companies and qualified personnel, emphasizing compliance with safety regulations, proper installation practices, routine inspections, and hose change procedures. An appendix contains detailed technical specifications, ambient conditions, lubricants, tightening torques, and a declaration of conformity.
Only use the pump to handle compatible fluids as recommended by the manufacturer and adhere to operating limits.
Ensure the pump is properly supported, not installed near extreme hot or cold sources, and that installation complies with local health and safety regulations.
Follow the hose change procedure: dismount the hose, then re-install the hose, port flanges, lubricant refill, and fit the inspection window.