VERDAMPER C-D-E, H and J Reducer Service Manual

Service manual for VERDAMPER C-D-E, H and J reducers covering replacement kits, disassembly, damper modification, calibration and testing.


VERDAMPER C-D-E, H and J Reducer Service Manual - cover page
Brand
VERDAMPER
Category
Other
Document type
Service Manual
Language
English
Pages
42
File format
PDF
File size
3.6 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
279856441D79F1AFF0CA2B1E4FEBC654

About this manual

This VERDAMPER reducer service manual covers the C-D-E reducer, the H-reducer, damper modification in the J-reducer, and testing and calibrating. It lists the required tools and reducer replacement kits, then gives step-by-step disassembly and replacement instructions for diaphragms, O-rings, the valve seat, locating pin, jet and pressure relief O-ring.

The final sections describe how to calibrate the test setup and how to test a reducer, including inlet pressure, outlet pressure and pressure-increase checks.

What's inside

  • Tools and products
  • C-D-E reducer
  • H-reducer
  • Damper modification in J-reducer
  • Testing / Calibrating
  • How to Calibrate the test procedure
  • Procedure for testing the reducer
  • Testing a reducer

Specifications

Diaphragm bolt torque2.5 Nm
Test inlet air pressure5 bar absolute
Factory default outlet pressure2.1-2.2 bar
Maximum outlet pressure increase0.15 bar
Maximum pressure setting testgreater than 2.6 bar absolute
Minimum pressure setting testless than 1.6 bar absolute
Coil test voltage12 V

Frequently asked questions

What torque is specified for the diaphragm bolt?

The manual specifies a torque setting of 2.5 Nm.

What is the factory default outlet pressure?

The outlet pressure should be 2.1-2.2 bar at factory default.

What inlet air pressure is used when testing the reducer?

The test uses inlet air at 5 bar absolute.

How much may the outlet pressure increase when the outlet valve is closed?

The pressure may increase by a maximum of 0.15 bar.