Service manual for VERDAMPER C-D-E, H and J reducers covering replacement kits, disassembly, damper modification, calibration and testing.
This VERDAMPER reducer service manual covers the C-D-E reducer, the H-reducer, damper modification in the J-reducer, and testing and calibrating. It lists the required tools and reducer replacement kits, then gives step-by-step disassembly and replacement instructions for diaphragms, O-rings, the valve seat, locating pin, jet and pressure relief O-ring.
The final sections describe how to calibrate the test setup and how to test a reducer, including inlet pressure, outlet pressure and pressure-increase checks.
| Diaphragm bolt torque | 2.5 Nm |
|---|---|
| Test inlet air pressure | 5 bar absolute |
| Factory default outlet pressure | 2.1-2.2 bar |
| Maximum outlet pressure increase | 0.15 bar |
| Maximum pressure setting test | greater than 2.6 bar absolute |
| Minimum pressure setting test | less than 1.6 bar absolute |
| Coil test voltage | 12 V |
The manual specifies a torque setting of 2.5 Nm.
The outlet pressure should be 2.1-2.2 bar at factory default.
The test uses inlet air at 5 bar absolute.
The pressure may increase by a maximum of 0.15 bar.