Service instruction for Ventura rapid sliding door systems covering door leaf, shaft, stoppers, filter regulator, safety, operation and torque settings.
This document is a maintenance manual for Ventura rapid sliding door systems, marked Service instruction SMRS Revision 4. It gives safety instructions and maintenance procedures for the door leaf in closed and open positions, the door shaft, soft stoppers, filter regulator and sensitive edge. It also covers operational and safety checks, torque settings and remarks.
The manual states that all instructions must be carried out without air or electric pressure unless mentioned otherwise. It specifies a nominal opening and closing cycle of 3.5 seconds, a pneumatic system pressure of 8 ± 1 bar, and the use of Q8 Rembrandt EP-21 multipurpose lithium-based grease where lubrication is required.
| Door leaf top clearance | 50 mm |
|---|---|
| Upper rail gap | 6 ± 2 mm |
| Pneumatic system pressure | 8 ± 1 bar |
| Opening/closing cycle time | nominal 3.5 sec |
For normal use of 0-230 open/close times per day, maintenance is required once per year.
The pneumatic system pressure should be between 8 ± 1 bar.
The gap should be consistently 6 ± 2 mm while the door opens and closes.
The manual specifies Q8 Rembrandt EP-21 multipurpose lithium-based grease.