Van der Valk Solar Systems ValkBox 3 Solar Panel Mounting System Installation Manual

Installation manual for the Van der Valk Solar Systems ValkBox 3 solar panel mounting system, covering ballast, safety and mounting steps.


Van der Valk Solar Systems ValkBox 3 Solar Panel Mounting System Installation Manual - cover page
Brand
Van der Valk Solar Systems
Category
Other
Document type
Installation Guide
Language
English
Pages
21
File format
PDF
File size
2.6 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
50F8E36F553E94D4B5AAD26E768B51EC

About this manual

The ValkBox 3 is a universal mounting system from Van der Valk Solar Systems for solar panels on flat roofs or ground surfaces up to a maximum pitch of 5 degrees. The manual covers safety instructions, ballast tables for the Netherlands and Belgium, components, and mounting steps including the clevis, curved supports, rubber tiles and hinge bolts.

The system requires ballast and is placed in the middle zone of the roof. It supports panels up to 2280 mm long and 926–1150 mm wide with an aluminium frame and M6 mounting holes, and roof coverings can be bitumen, EPDM or concrete.

What's inside

  • Disclaimer
  • Safety instructions
  • Required ballast
  • Components
  • Mounting the clevis
  • Mounting the curved supports
  • Mounting panel options
  • Placing the rubber tiles
  • Position the ballast
  • Tighten hinge bolts B1

Specifications

Panel lengthUp to 2280 mm
Panel width926 - 1150 mm
Maximum roof pitch5 degrees
Roof coveringBitumen, EPDM and concrete
Panel frameAluminium frame with M6 mounting holes
Maximum tiles per system17 tiles (30x30x4.5 cm)
Maximum ballast weight153 kg
Standard warranty10 years

Frequently asked questions

What panel dimensions does the ValkBox 3 support?

The manual lists panel width as 926–1150 mm and panel length up to 2280 mm.

What is the maximum roof pitch for the ValkBox 3?

It may only be placed on flat roofs or ground surfaces up to a maximum pitch of 5 degrees.

How much ballast is required?

The required ballast depends on wind area and building height; the minimum extra ballast in G1 and G2 is 2 x 1 tile (2 x 9 kg).

When must the system be mechanically fixed to the roof?

If the roof inclination is 5 degrees or more, the system must always be mechanically fixed to the roof construction.