USG Durock Brand Cement Board with EdgeGuard Installation Guide

USG Durock Brand Cement Board with EdgeGuard installation guide covering cutting, floor, countertop, wall and ceiling installation, tile layout and safety.


USG Durock Brand Cement Board with EdgeGuard Installation Guide - cover page
Brand
USG
Category
Other
Document type
Installation Guide
Language
English
Pages
8
File format
PDF
File size
5.6 MB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
10538570BEC8ACB49F56678755DBFAAC

About this manual

USG Durock Brand Cement Board with EdgeGuard is a cement backerboard for floors, countertops, walls and ceilings. The guide says it has a smooth side for mastic and a rough side for mortar, is water durable and mold resistant, and is warranted for interior and exterior application.

The document covers what you'll need, cutting, floor, countertop, wall and ceiling installation, planning tile layout, installing ceramic tile, waterproofing and safety. It gives thickness options and substrate, stud and fastener spacing requirements, plus handling precautions for dust containing silica.

What's inside

  • What You'll Need
  • Cutting
  • Floor Installation
  • Countertop Installation
  • Wall & Ceiling Installation
  • Planning Your Tile Installation
  • Installing Ceramic Tile
  • Waterproofing
  • Safety First

Specifications

Available thicknesses for floors1/4 in. (6 mm), 1/2 in. (12.7 mm), 5/8 in. (16 mm)
Minimum subfloor thickness5/8 in. (16 mm)
Minimum countertop base thickness3/4 in. (19 mm)
Maximum stud spacing16 in. (406 mm) o.c.
Maximum allowable deflectionL/360
Fastener spacing for walls8 in. (203 mm) o.c.
Fastener spacing for ceilings6 in. (152 mm) o.c.
Mold resistance rating0 per ASTM G21
ASTM D3273 score10 out of 10
Warranty30-year limited warranty

Frequently asked questions

What thicknesses does USG Durock Brand Cement Board with EdgeGuard come in?

For floors and countertops, the guide lists 1/4 in. (6 mm), 1/2 in. (12.7 mm) and 5/8 in. (16 mm) thicknesses; walls and ceilings use 1/2 in. and 5/8 in. only.

Can the cement board be used with vinyl flooring?

No; the guide says it is not for use with vinyl flooring.

How should I cut the panels?

Use a knife and straightedge to cut panels to size; use a power saw only if it has a dust collection device.

How is mold resistance rated?

The board receives a rating of 0 for no mold growth under ASTM G21 and scores 10 out of 10 on ASTM D3273.