Technical guidelines for designing and implementing floodlighting systems in football stadiums to meet UEFA competition requirements.
This document provides a comprehensive set of recommendations for the design and implementation of lighting systems in football stadiums. It is tailored to meet UEFA's specific requirements for different levels of competition, ensuring optimal lighting conditions for players, officials, spectators, and broadcasters. The guide was developed in consultation with International Illuminance Services (IIS) to encourage the adoption of best practices in pitch illuminance system design.
| Elite level A average horizontal illuminance | > 2,000 lux |
|---|---|
| Elite level A uniformity U1h | > 0.50 |
| Elite level A vertical illuminance 0° average | > 1,500 lux |
| Elite level A flicker factor average | < 5% |
| Elite level A colour temperature | 5,000–6,200K |
| Elite level A colour rendering | ≥ 80 Ra |
| Elite level A glare rating | < 50 |
| Elite level A maintenance factor | 0.85 |
The minimum requirement for non-broadcast matches is 350 lux.
Elite level A stadiums require a uniformity U1h greater than 0.50 and U2h greater than 0.70.
The maximum flicker factor allowed is 5%.