Trycom TRP-C31M MODBUS TCP to RTU/ASCII Gateway User's Manual

Trycom TRP-C31M user's manual for a MODBUS gateway that links MODBUS TCP networks with RS-232, RS-422, and RS-485 RTU/ASCII devices.


Trycom TRP-C31M MODBUS TCP to RTU/ASCII Gateway User's Manual - cover page
Brand
Trycom
Category
Converter
Document type
User Manual
Language
English
Pages
28
File format
PDF
File size
1.3 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
92B846DC2DDE2A2F951AB75B1969FB3E

About this manual

The Trycom TRP-C31M is a MODBUS gateway that lets legacy MODBUS RTU/ASCII devices operate on a MODBUS TCP network. It can act as a MODBUS TCP master toward serial slaves, supporting up to 31 slaves, or as a MODBUS RTU/ASCII master toward up to 8 MODBUS TCP slaves with user-specified UID ranges.

The manual covers panel layout, LED indicators, reset button, DIP switch modes, power, Ethernet and serial connections, DB9 pin configuration, serial port operating modes, TRP-C3XM Manager software installation, Telnet configuration, and firmware upgrading.

What's inside

  • Introduction
  • Features
  • Specifications
  • Hardware Description
  • Panel Layout
  • Block Diagram
  • LED Display
  • Reset Button
  • DIP Switches
  • Install TRP-C31M

Specifications

Ethernet support10/100 Mbps
Serial interfacesRS-232, RS-422, and RS-485
Data rate110 bps to 230.4 kbps
Paritynone, even, odd, mark, space
Data bits5, 6, 7 or 8
Stop bits1, 1.5 or 2
ProtocolsTCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP
Power requirements9~15 VDC / 500 mA
Operating temperature0 to 60 °C
Storage temperature-20 to 70 °C
Humidity10~90% Non-Condensing
Dimensions151mm x 77mm x 26mm
Weight377g
Serial connectionDTE – BD-9 male
Output buffer64K bytes
Input buffer8K bytes
Maximum MODBUS TCP slaves8
Maximum MODBUS serial slaves31

Frequently asked questions

What is the TRP-C31M used for?

It is a MODBUS gateway that allows legacy MODBUS RTU/ASCII devices to operate on a MODBUS TCP network, linking serial masters or slaves with TCP masters or slaves.

How many MODBUS TCP slaves can the TRP-C31M connect to?

When used as a MODBUS RTU/ASCII master, it can connect up to 8 MODBUS TCP slaves, and a UID range can be specified for each slave.

How is the TRP-C31M configured over Ethernet?

The TRP-C3XM Manager software provides configuration over Ethernet, and the unit can also be configured through Telnet or the Web Server.

What does Loop back Mode do?

In Loop back Mode all data is sent back immediately, which makes connection testing easy.

How is firmware upgraded on the TRP-C31M?

Download the new .hex file from the Trycom website, set the unit to upgrade mode, connect with a null modem cable, and use the Firmware Upgrade button in the TRP-C3XM Manager software.

Download PDF (1.3 MB)