Operating manual for Travaini TRVK single-stage and TRSK two-stage liquid ring vacuum pumps, covering installation, start-up, maintenance and safety.
This manual applies to Travaini single-stage liquid ring vacuum pumps series TRVK and TRSK, including pump/motor assemblies or HYDROSYS systems. It covers general and safety instructions, emergency response, pump outlines, uncrating, storage, mounting, alignment, electrical and piping connections, accessories, installation schematics, engineering data, pre-start checks, starting, operating, stopping, maintenance, troubleshooting, repair, and spare parts.
The manual states that the pump is to be used only for the applications specified on the confirming order and that failure to follow its instructions and recommendations voids the manufacturer's warranty.
| TRVK capacity | to 22500 m3/h |
|---|---|
| TRVK maximum vacuum | 40 mbar |
| TRSK capacity | to 30000 m3/h |
| TRSK maximum vacuum | 180 mbar |
| Service liquid temperature | not exceed 80 C |
| Handled gas temperature | maximum 100 C |
| Service liquid density | 800 to 1200 g/dm3 |
| Service liquid viscosity | less than 40 cSt |
It must be clean, non-abrasive, free of solids, no hotter than 80 C, with density between 800 and 1200 g/dm3 and viscosity less than 40 cSt.
No, unless POMPETRAVAINI gives prior written consent.
Immediately disconnect the electrical power, alert maintenance personnel, and carry out the recommended starting procedures after correcting the problem.
Authorised personnel, in accordance with local codes.